• PAPANIKOLI 1A – 1077 – NICOSIA – CYPRUS
  • 0035722000125
  • This email address is being protected from spambots. You need JavaScript enabled to view it.
Loading...
ubiquiti_F-POE-G2.jpg
UBIQUITI_U_POE_af.jpg UBIQUITI_U_POE_af.jpg

Ubiquiti F-POE-G2 Optical Data Transport for Outdoor POE Devices

Product Code:
F-POE-G2
Manufacturer: Ubiquiti
Sales price 39,50 €(Includes 19% VAT)
Sales price without tax 33,19 €
Product Availability:
Show Shipping Cost:
  • Description
  • Specifications
  • Downloads
Ubiquiti F-POE-G2 Optical Data Transport for Outdoor POE Devices

Fiber + Power Solution for Outdoor PoE Devices 
Overcome PoE limitations with the next-generation FiberPoE™, model F-POE-G2. The FiberPoE Gen 2 is a low-cost solution for outdoor deployments that require long-distance runs to reach the PoE device. Deployments with the FiberPoE Gen 2 provide significant EMI and ESD protection over typical PoE installations. The FiberPoE Gen 2 also features a durable, weatherproof form factor and enhanced surge protection. 

Separate Data and Power Transport 
PoE is ideal for indoor or short-run installations. However, for outdoor, long-distance installations, PoE becomes vulnerable to EMI and is limited to 100 meters with correlated power loss. With the FiberPoE Gen 2, data and power are transported on separate cables to greatly improve data integrity and enable much longer cable runs.
The FiberPoE Gen 2 provides Gigabit bi-directional data transport between twisted-pair Ethernet cable and fiber optic cable, and injects DC power to the Ethernet cable for passive PoE. Use one FiberPoE Gen 2 device as an Fiber‑to‑Ethernet Converter, or a pair of FiberPoE Gen 2 devices to create a Fiber Bridge.

Enhanced Surge Protection 
Featuring a built-in high-current Gas Discharge Tube (GDT) for the DC terminal block and PoE port, the FiberPoE Gen 2 delivers enhanced surge protection. The added GDT support effectively protects against lightning and other power surges. 

Fiber Optic Data Transport 
Using fiber optic cable for data transport significantly reduces electrostatic discharge (ESD) failures and electromagnetic interference (EMI). Data integrity is also sustained in runs beyond 100 meters, the limit of Ethernet over twisted-pair cable.
The FiberPoE Gen 2 supports a 1G SFP module and 24V or 50V power from a DC power cable or PoE cable.

Integrated Fiber Cable Strain Relief 
An integrated strain relief system was thoughtfully designed to fit inside the FiberPoE Gen 2 cover for added protection and a cleaner installation.

Application Examples 
The following are typical use cases for the FiberPoE Gen 2.
Data Options 
1. Fiber-to-Ethernet Converter One FiberPoE Gen 2 at the top of the tower is used to convert fiber to Ethernet at the radio. At the base of the tower, the fiber optic cable connects directly to a fiber switch or router.
2. Fiber Bridge Two FiberPoE Gen 2 devices, one at the base and one at the top of the tower, are used to provide a fiber optic data link for protection from EMI events that can cause equipment damage or signal integrity issues.

Warranty (Repair - Replacement)
24 months



Specifications
Dimensions 196.4 x 93.5 x 32.4 mm
Weight 288 g
Enclosure White Polycarbonate
Interface Connections (1) 1 Gbps SFP Port
(1) DC Terminal Block
(1) DC RJ45 Port DC Injection
(1) 1000 Mbps Ethernet PoE Port
*10/100 Mbps Ethernet not supported.
Typical Power Consumption 1.5W
Power Method DC Terminal Block, 2-Wire, 24VDC or 50VDC
DC In RJ45 Port, 2-Pair (4, 5+; 7, 8-) (24VDC Input), or
4-Pair (24VDC or 50VDC Input) Passthrough
PoE RJ45 Port, 2-Pair (4, 5+; 7, 8-) (24VDC Input), or
4-Pair (24VDC or 50VDC Input) PoE Passthrough
PoE Output PoE RJ45 Port, 2-Pair (4, 5+; 7, 8-) (24VDC), or
4-Pair (24VDC or 50VDC) PoE
DC Output Terminal Block, 2-Wire (24VDC or 50VDC)
Input DC Voltage 16 to 57V
Surge Protection Built-In High-Current Gas Discharge Tube
for DC Terminal Block and PoE Port
LED White: Power On
Blue: Connected
Blue (Flashing): Activity
Operating Temperature -40 to 60° C**
**May be further restricted by the operating
temperature range of the SFP module being used.
Operating Humidity 10 to 95% Noncondensing
ESD/EMP Protection ± 24KV Contact / Air for Ethernet
Certifications CE, FCC, IC

B2B ACCOUNTS

© Waveform 2017, All rights reserved

LOGIN